Objective: There have been substantial reductions in motor vehicle crash–related child fatalities due to advances in legislation, public safety campaigns, and engineering. Less is known about non-traffic injuries and fatalities to children in and around motor vehicles. The objective of this study was to describe the frequency of various non-traffic incidents, injuries, and fatalities to children using a unique surveillance system and database.
Methods: Instances of non-traffic injuries and fatalities in the United States to children 0–14 years were tracked from January 1990 to December 2014 using a compilation of sources including media reports, individual accounts from families of affected children, medical examiner reports, police reports, child death review teams, coroner reports, medical professionals, legal professionals, and other various modes of publication.
Results: Over the 25-year period, there were at least 11,759 events resulting in 3,396 deaths. The median age of the affected child was 3.7 years. The incident types included 3,115 children unattended in hot vehicles resulting in 729 deaths, 2,251 backovers resulting in 1,232 deaths, 1,439 frontovers resulting in 692 deaths, 777 vehicles knocked into motion resulting in 227 deaths, 415 underage drivers resulting in 203 deaths, 172 power window incidents resulting in 61 deaths, 134 falls resulting in 54 deaths, 79 fires resulting in 41 deaths, and 3,377 other incidents resulting in 157 deaths.
Conclusions: Non-traffic injuries and fatalities present an important threat to the safety and lives of very young children. Future efforts should consider complementary surveillance mechanisms to systematically and comprehensively capture all non-traffic incidents. Continued education, engineering modifications, advocacy, and legislation can help continue to prevent these incidents and must be incorporated in overall child vehicle safety initiatives. 相似文献
The study addresses the potential of using concentrated solar power plants (CSPs) as a sustainable alternative of clean energy generation in the Mediterranean region and, in particular, in its North Africa shore. This location presents attractive conditions for the installation of CSPs, in particular high solar irradiation, good manpower concentration, and proximity and availability of water resources for condenser cooling. Energetic, exergetic, and economic analyses were conducted taking into consideration a particular type of CSPs - the parabolic trough concentrated solar power plant, which incorporates the most proven technology and it is already used in Southern Europe (Spain). In addition, the study considered the impact of project financing and incentives on the cost of energy. The combination of higher values for performance and potentially lower levelized cost of electricity (LCE) for the North Africa Mediterranean Rim than the South of Spain region can yield a very favorable return for the invested capital. Tripoli compared to Almeria presented superior performance and potentially lower LCE values ($0.18/kWh versus $0.22/kWh). This is significant, even when it is taken into consideration the fact that the plant in Tripoli, despite a relatively modest capacity factor of 34%, has a large gross power output of 173,886 MWhe. In addition, the implementation at the Tripoli location of a plant similar to the Anadsol plant has a slight advantage (2–3%) in terms of overall efficiency. 相似文献
ABSTRACT In this study, a three-dimension (3D) computational model was proposed to investigate the flow and heat transfer characteristics of the intake grilles of two different fuel cell vehicles. The models of the intake grilles were constructed according to the actual sizes of two vehicles, namely, Roewe 950 and Toyota Mirai, considering the heat dissipation unit to simplify the heat transfer model of the vehicle. The results showed that relative to Roewe 950, Mirai intake air flow rate was approximately 10% higher, the heat transfer capacity was approximately 7% higher, and the intake grille area was larger. The coolant outlet temperature of Mirai was lower than that of Roewe 950, which was beneficial for the long term and stable operation of a fuel cell. This comparative study provided guidance for the intake grille and radiator design of fuel cell vehicles. The only difference between fuel cell vehicles on the market and conventional vehicles was that in the former, the internal combustion engine was replaced with a fuel cell stack, which had insufficient heat transfer capacity because of the reducing temperature difference. Increasing the intake grille area and the heat exchange capacity of the radiator were the key issues for the development of fuel cell vehicles. In this study, an optimal window opening angle of the radiator fin of 23° provided a maximal heat transfer coefficient. 相似文献
When accounting the CO2 emissions responsibility of the electricity sector at the provincial level in China,it is of great significance to consider the scope of both producers’ and the consumers’ responsibility,since this will promote fairness in defining emission responsibility and enhance cooperation in emission reduction among provinces.This paper proposes a new method for calculating carbon emissions from the power sector at the provincial level based on the shared responsibility principle and taking into account interregional power exchange.This method can not only be used to account the emission responsibility shared by both the electricity production side and the consumption side,but it is also applicable for calculating the corresponding emission responsibility undertaken by those provinces with net electricity outflow and inflow.This method has been used to account for the carbon emissions responsibilities of the power sector at the provincial level in China since 2011.The empirical results indicate that compared with the production-based accounting method,the carbon emissions of major power-generation provinces in China calculated by the shared responsibility accounting method are reduced by at least 10%,but those of other power-consumption provinces are increased by 20% or more.Secondly,based on the principle of shared responsibility accounting,Inner Mongolia has the highest carbon emissions from the power sector while Hainan has the lowest.Thirdly,four provinces,including Inner Mongolia,Shanxi,Hubei and Anhui,have the highest carbon emissions from net electricity outflow- 14 million t in 2011,accounting for 74.42% of total carbon emissions from net electricity outflow in China.Six provinces,including Hebei,Beijing,Guangdong,Liaoning,Shandong,and Jiangsu,have the highest carbon emissions from net electricity inflow- 11 million t in 2011,accounting for 71.44% of total carbon emissions from net electricity inflow in China.Lastly,this paper has estimated the emission factors of electricity consumption at the provincial level,which can avoid repeated calculations when accounting the emission responsibility of power consumption terminals(e.g.construction,automobile manufacturing and other industries).In addition,these emission factors can also be used to account the emission responsibilities of provincial power grids. 相似文献
Air pollution in the workplace environment due to industrial operation have been found to cause serious occupational health
hazard. Similarly, heat stress is still most neglected occupational hazard in the tropical and subtropical countries like
India. The hot climate augments the heat exposure close to sources like furnaces. In this study an attempt is made to assess
air pollution and heat exposure levels to workers in the workplace environment in glass manufacturing unit located in the
State of Gujarat, India. Samples for workplace air quality were collected for SPM, SO2, NO2 and CO2 at eight locations. Results of workplace air quality showed 8-hourly average concentrations of SPM: 165–9118 μg/m3, SO2: 6–9 μg/m3 and NO2: 5–42 μg/m3, which were below the threshold limit values of workplace environment. The level of CO2 in workplace air of the plant was found to be in the range 827–2886 μg/m3, which was below TLV but much higher than the normal concentration for CO2 in the air (585 mg/m3). Indoor heat exposure was studied near the furnace and at various locations in an industrial complex for glass manufacturing.
The heat exposure parameters including the air temperature, the wet bulb temperature, and the globe parameters were measured.
The Wet Bulb Globe Temperature (WBGT), an indicator of heat, exceeded ACGIH TLVs limits most of the time at all the locations
in workplace areas. The recommended duration of work and rest have also been estimated. 相似文献